Call Us Today: 800-523-1266

103 Queens Drive | King of Prussia, PA

            ISO 9001:2015 Certified

ER410NiMo

Class: ER410NiMo

AWS: A5.9

Conforms to Certification: AWS A5.9                   ASME SFA A5.9

Weld Process Used for Mig (GMAW) and Submerged Arc (SAW)

AWS Chemical Composition Requirements
C = 0.06 max
Cr = 11.0 – 12.5
Ni = 4.0 – 5.0
Mo = 0.4 – 0.7
Mn = 0.60 max
Si = 0.50 max
P = 0.03 max
S = 0.03 max
Cu = 0.75 max

Available Sizes
Diameter X Spool Sizes Diameter X Coil Sizes
.025 x 2#, 10#, 25# 5/64 x mill coil
.030 x 2#, 10#, 25#, 33# 3/32 x 60# & mill coil
.035 x 2#, 10#, 25#, 33# 1/8 x 60# & mill coil
.045 x 2#, 10#, 25#, 33# 3/16 x 60# & mill coil
1/16 x 10#, 25#, 33# also 60# 5/32 x 60# & mill coil

Application
ER410NiMo wire is used primarily to weld cast and wrought material of similar chemical composition. It is recommended using preheat and inter-pass temperature of not less than 300ºF. Post weld heat treatment should not exceed 1150ºF, higher temperature may result in hardening.

Deposited Chemical Composition % (Typical)
C = 0.02 Mo = 0.55 P = 0.012
Cr = 11.8 Mn = 0.45 S = 0.009
Ni = 4.50 Si = 0.40

 

Mechanical Properties (R.T.) 
Yield Strength 92,000psi
Tensile Strength 118,000psi
Elongation 20%

Deposited All Weld Metal Properties
Data is typical for ER410NiMo weld metal deposited by Mig using Argon + 2% oxygen as the shielding gas. Data on sub-arc is not presented, as sub-arc is dependent on the type of flux used.

Recommended Welding Parameters
GMAW “Mig Process” Reversed Polarity
Wire Diameter Wire Feed Amps Volts Shielding Gas Gas CFH
Short Arc Welding .030 13-26 40-120 16-20 Argon+2% O2 25
.035 13-26 60-140 16-22 Argon+2% O2 25
Spray Arc Welding .035 20-39 140-220 24-29 Argon+2% O2 38
.045 16-30 160-260 25-30 Argon+2% O2 38
1/16 10-16 230-350 27-31 Argon+2% O2 38

Other shielding Gases may be used for Mig welding. Shielding gases are chosen taking Quality, Cost, and Operability into consideration

Recommended Welding Parameters
SAW “Submerged Arc Welding Process”   Reversed Polarity Suggested
Wire Diameter Amps Volts
3/32 250-450 28-32
1/8 300-500 29-34
5/32 400-600 30-35
3/16 500-700 30-35

Both Agglomerated and fused fluxes can be used for submerged arc welding.
Note: The chemical composition of the flux mainly affects the chemistry of the weld metal and consequently its corrosion resistance and Mechanical properties.