Class: ER502
AWS: A5.9
Conforms to Certification: AWS A5.9 ASME SFA A5.9
Weld Process Used for Tig (GTAW)
AWS Chemical Composition Requirements
C = 0.10 max
Cr = 4.6 – 6.0
Ni = 0.60 max
Mo = 0.45 – 0.65
Mn = 0.60 max
Si = 0.50 max
P = 0.03 max
S = 0.03 max
Cu = 0.75 max
Available Sizes
.030 x 36
.035 x 36
.045 x 36
1/16 x 36
3/32 x 36
1/8 x 36
3/16 x 36
5/32 x 36
Application
ER502 is used for welding 502 base materials, frequently tube or pipe. Preheating and post-weld heat treatment is required.
Deposited Chemical Composition % (Typical) | ||
C = 0.07 | Mo = 5.0 | P = 0.015 |
Cr = 5.45 | Mn = 0.44 | S = 0.006 |
Ni = 0.45 | Si = 0.04 | Cu = 0.20 |
Mechanical Properties (R.T.) | |
Yield Strength | 60,500psi |
Tensile Strength | 78,500psi |
Elongation | 32% |
Deposited All Weld Metal Properties
Data is typical for ER502 weld metal deposited by Tig using 100% Argon as the shielding gas.
Recommended Welding Parameters | |||
GTAW “Tig Process” | |||
Wire Diameter | Amps DCSP | Volts | Shielding Gas |
.035 | 60-90 | 12-15 | Argon 100% |
.045 | 80-110 | 13-16 | Argon 100% |
1/16 | 90-130 | 14-16 | Argon 100% |
3/32 | 120-175 | 15-20 | Argon 100% |
Note: Parameters for tig welding are dependent upon plate thickness and welding position.